Juice Goose
JUICE GOOSE PRODUCTS POWER SEQUENCING: CQ SERIES

CQ Series  PRODUCTS
CQ-1520
CQ-2000
CQ-2200
CQ-3000
CQ-PD1-4
RC5
RC-DM2

RC5 with Rotary Knob Switch
RC5 with Keyswitch
Single Sequenced 20 AMP Power Distribution System with Remote Control Capability
   

CQ-2000

 
Single Sequenced 20 AMP Power Distribution System with Remote Control Capability


The CQ-2000 is a 20 amp hardwire device with a single sequence event. Like the other CQ devices it has sequence signal line input and output ports to allow it to be daisy chained with any number of other CQ devices. For a similar unit with 2 sequence events, see the CQ-2200.

The CQ-2000 back box conveniently mounts to a surface with four mounting holes on the back plate. The front panel assembly holds all the active components and circuitry. After main AC power is attached to the CQ-2000 circuit board, the front panel assembly is attached to the back box. Snap in the RJ-11 style CQ signal cable and plug in the equipment. That's it!

The CQ-2000 is available in an isolated ground version (CQ-2000-IG).


All CQ Series products feature multiple pairs of power outputs, Power Pods(TM), which are turned on every 2 seconds. Equipment to be powered plugs directly into the CQ device. All CQ models have the ability to transmit a sequence command to another CQ unit or to receive a remote sequence command from another CQ unit or from an RC5 Remote Control/Monitor accessory or any contact closure. In this way, any CQ Series product can be a master or slave unit.

A power sequencing system can be built from several CQ Series products which can be selected depending on the specific requirements of a particular installation: number and location of circuits, current (amps) requirement of circuit, number of control locations, number of sequence events. Select only the specific CQ Series products to meet a specific requirement.

The time delay between sequence events is 2 seconds, controlled by the CQ Series software. The order in which powered equipment is turned on depends on which Pod that equipment is plugged into and where that Pod is located relative to the entire CQ system.

REMOTE OPERATION

CQ DEVICES - Any CQ device can act as a remote controller and operate in concert with other CQ devices. Each can be a master or a slave unit. Any number of CQ devices can be connected in a daisy chain fashion.

REMOTE CONTACT CLOSURE - As an alternative, to control the sequencing function, the Signal Input for the first CQ device can be connected to a latching contact closure. Juice Goose recommends a single pole double throw device in order to maintain one of two required contacts. Computer controlled devices such as those produced by AMX will also work. To view an Adobe PDF format of this connection, click here.

RC-5 KEY SWITCH - The RC-5 connects directly to the Signal Input port on the CQ product. It controls and monitors the CQ system functions.

SEQUENCE SWITCH - Without a contact closure on the Signal Input the switch on the CQ chassis will control its operation. This switch has three positions: Sequence Up, Sequence Down and Manual On. The Sequence Up and Down positions will activate the sequence process for that CQ unit and cause it to activate any units connected to the Signal Output port. In the unlikely event of a failure of a particular CQ unit, the Manual On switch position allows fail-safe activation of the CQ device.(Note: the Manual On option does not provide sequencing.)


SIGNAL CONNECTIONS

All CQ products can be easily connected by way of a standard 6 wire, RJ-11 modular phone cable with secure, snap-in type connectors.

Because each CQ device has self contained power sequence circuitry, this communication link allows any CQ device to act as a power sequencer and controller to cascade activation for any number of other CQ's in a complete directed electric power activation system.

Signal connections require little installation time and are reliable because the modular nature of the signal carrier reduces the risk of miswiring. Assembly of the signal wire to the modular connectors requires use of AMP Modular Crimper Tool Model #1-231652-8, or equivalent.

The orientation of the wires is important and conforms to standards for telephone line connection. The orientation should be the same for Signal Input and Output cables. It is best to insert the cable into the first connector so that the black wire is on the left. The second connector should be attached so the black wire is on the right when viewed from the same perspective as the first.

The signal communication between the CQ units utilizes a current loop sensing system. Therefore, signal loss and external interference will not affect the reliability of the sequencing as can happen the other voltage related types of communication. Remote control and monitoring of the sequencing process can be accomplished with the RC-5 accessory which is available in either wall or rack mount models.

 


DETAIL SPECIFICATIONS SPECIFICATIONS

CHASSIS  ALL UNITS 16 AWG Steel
DIMENSIONS (IN) CQ-1520 1.75H X 19W X 7D
  CQ-2000, 2200 & 3000 5.5H X 6.4W X 3.75D
  CQ-PD1-4 32L X 3.5W X 1.75D
WEIGHT (LBS) CQ-1520 10.0
  CQ-2000 & 2200 5.0
  CQ-3000 6.0
  CQ-PD1-4 13.0
CIRCUIT BREAKER CQ-1520 Back Panel, 20A
  CQ-2000 & 2200 Side Panel, 20A
  CQ-3000 Side Panel, 30A
  CQ-PD1-4 None
POWER INPUT CQ-1520 7 Foot, 12/3 SJWT with NEMA 5/20P
  CQ-2000, 2200 & 3000 Hardwire with Crimp Tight Fast-on Terminals
  CQ-PD1-4 4 ft. wire harness std.
VOLTAGE ALL UNITS 120 VAC @ 60 HZ
POWER OUTPUTS CQ-1520 NEMA 5/15R, Unswitched (1)
NEMA 5/20R, Seq'd (6)
  CQ-2000 Two NEMA 5/20R, Seq'd
  CQ-2200 Four NEMA 5/20R, Seq'd
  CQ-3000 One NEMA 5L/30R, Seq'd
  CQ-PD1-4 Eight NEMA 5/20R, Seq'd
SEQUENCE EVENTS CQ-1520 Three
  CQ-2000 One
  CQ-2200 Two
  CQ-3000 One
  CQ-PD1-4 Four
RELAY CURRENT RATING CQ1520, 2000, 2200 and PD1 30 Amps
  CQ3000 50 Amps
POWER LINE FILTRATION CQ-1520 48dB @ 30 Mhz
  CQ-2000, 2200, 3000 & PD1 None
VOLTAGE SPIKE PROTECTION CQ-1520 3 MOV Matrix
  CQ-2000, 2200, 3000 & PD1 None
MONITOR FEATURES ALL Except PD1 Front Panel LEDs for Processor and Sequence Function

Commercial Product Pricing Policy

The Juice Goose line of power sequencing products are sold for installation by professional contractors in the commercial audio and video industries. For this reason, retail prices are not published for these items. For additional information on the cost of the power sequencing line, please consult your contractor or contact us for referral to an authorized reseller.

   
spacer


HOME | CONTACT US | FEEDBACK | CUSTOMER CARE | WARRANTY | SALES REPRESENTATIVES

Juice Goose Homepage